Page content:
Jumper Wire (Y)
- Operating Voltage: 600 V
According To VDE 0815 & 812
Construction:
1- Solid plain (or tinned) annealed copper wire
2- PVC insulation type YI 1
Min. Insulation Resistance at 20^ C: 20 Mohm.Km
- Application:
Single core for use in small apparatus, switching and intercom system and for data transmission.
No. of Wires Conductor/Core dia. | Insulation Thickness (mm) | Approx. Overall dia. (mm) | Approx. Cable Weight (kg/km) | DC Resistance (ohms/km) |
---|---|---|---|---|
1×0.6/1.4 | 0.4 | 1.4 | 4.2 | 65 |
2×0.6/1.4 | 0.4 | 2.8 | 8.5 | 65 |
3×0.6/1.4 | 0.4 | 3.0 | 12.8 | 65 |
4×0.6/1.4 | 0.4 | 3.4 | 17.0 | 65 |
1×0.8/1.6 | 0.4 | 1.6 | 6.5 | 36.6 |
2×0.8/1.6 | 0.4 | 3.2 | 13.2 | 36.6 |
3×0.8/1.6 | 0.4 | 3.4 | 19.9 | 36.6 |
4×0.8/1.6 | 0.4 | 3.9 | 26.5 | 36.6 |
Jumper Wire (YV)
- Operating Voltage:
500 V for 0.9 core Dia.
900 V for 1.1 to 2.2 mm core Dia.
1500 for 2.8 mm core Dia.
According To VDE 0815 & 812
Construction:
1- Solid tinned annealed copper wire
2- PVC insulation type YI 3
- Application:
For use in telephone wiring and signal installation in premises.
- Application:
No. of Wires Conductor/Core dia. | Insulation Thickness (mm) | Approx. Overall dia. (mm) | Approx. Cable Weight (kg/km) | DC Resistance (ohms/km) |
---|---|---|---|---|
1×0.5/0.9 | 0.2 | 0.9 | 2.5 | 92.2 |
2×0.5/0.9 | 0.2 | 1.8 | 5.0 | 95.0 |
3×0.5/0.9 | 0.2 | 2.0 | 7.5 | 95.0 |
4×0.5/0.9 | 0.2 | 2.2 | 10 | 95.0 |
1×0.5/1.1 | 0.3 | 1.1 | 3.0 | 92.2 |
2×0.5/1.1 | 0.3 | 2.2 | 6.0 | 95.0 |
1×0.6/1.1 | 0.25 | 1.1 | 3.7 | 64.0 |
2×0.6/1.1 | 0.25 | 2.2 | 7.5 | 66.0 |
3×0.6/1.1 | 0.25 | 2.4 | 11.0 | 66.0 |
4×0.6/1.1 | 0.25 | 2.7 | 15.0 | 66.0 |
No. of Wires Conductor/Core dia. | Insulation Thickness (mm) | Approx. Overall dia. (mm) | Approx. Cable Weight (kg/km) | DC Resistance (ohms/km) |
---|---|---|---|---|
1×0.6/1.4 | 0.4 | 1.4 | 4.5 | 65.0 |
2×0.6/1.1 | 0.4 | 2.8 | 9.0 | 66.0 |
3×0.6/1.1 | 0.4 | 3.0 | 13.5 | 66.0 |
4×0.6/1.1 | 0.4 | 3.4 | 18.0 | 66.0 |
5×0.6/1.1 | 0.4 | 3.8 | 23.0 | 66.0 |
1×0.8/1.4 | 0.3 | 1.4 | 6.0 | 36.0 |
2×0.8/1.4 | 0.3 | 2.8 | 12.0 | 36.7 |
1×1.0/1.8 | 0.4 | 1.8 | 10.0 | 22.8 |
2×1.0/1.8 | 0.4 | 3.6 | 20.0 | 23.3 |
1×1.4/2.2 | 0.4 | 2.2 | 17.5 | 11.6 |
1×1.8/2.8 | 0.5 | 2.8 | 28.0 | 7.1 |
Telephone Cables A2Y (ST) 2Y
- Similar to VDE 0816 & IEC 60708:
Construction:
1- Solid plain ( or tinned) annealed copper conductor
2- HDPE insulation type III ASTM D 1248
3- Static Screen: polyester tape + drain wire + AL polyester
4- LDPE black sheath type I ASTM D1248
5- Galvanized steel wire (if required)
6- Outer sheath: PE black
- Application:
For use in outdoor telecommunication installation in dry and damp places, but also in internal network open under ground where better mechanical protection is required we offer Armored with Galvanized steel wire.
Number of cores upon request
Conductor size 0,8 & 0.9mm upon request
Detail cable construction upon request
No. of Pairs | Conductor Dia. (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|
2.0 | 0.4 | 1.0 | 4.8 | 22 |
4.0 | 0.4 | 1.0 | 5.5 | 28 |
6.0 | 0.4 | 1.0 | 6.1 | 36 |
8.0 | 0.4 | 1.0 | 6.4 | 40 |
10 | 0.4 | 1.0 | 7.8 | 53 |
20 | 0.4 | 1.2 | 8.4 | 89 |
30 | 0.4 | 1.4 | 11.4 | 129 |
40 | 0.4 | 1.4 | 11.5 | 158 |
50 | 0.4 | 1.4 | 13.4 | 191 |
100 | 0.4 | 1.8 | 18.6 | 377 |
No. of Pairs | Conductor Dia. (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|
2.0 | 0.5 | 1.0 | 5.8 | 30 |
4.0 | 0.5 | 1.0 | 6.5 | 39 |
6.0 | 0.5 | 1.0 | 7.5 | 50 |
8.0 | 0.5 | 1.0 | 7.9 | 63 |
10 | 0.5 | 1.0 | 9.1 | 74 |
20 | 0.5 | 1.2 | 11.3 | 135 |
30 | 0.5 | 1.4 | 14.2 | 202 |
40 | 0.5 | 1.4 | 15.8 | 258 |
50 | 0.5 | 1.4 | 16.5 | 302 |
100 | 0.5 | 1.8 | 24.2 | 580 |
No. of Pairs | Conductor Dia. (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|
2.0 | 0.6 | 1.0 | 6.4 | 34 |
4.0 | 0.6 | 1.0 | 6.6 | 46 |
6.0 | 0.6 | 1.0 | 8.1 | 63 |
8.0 | 0.6 | 1.0 | 8.7 | 80 |
10 | 0.6 | 1.0 | 9.4 | 100 |
20 | 0.6 | 1.2 | 11.9 | 176 |
30 | 0.6 | 1.4 | 14.25 | 258 |
40 | 0.6 | 1.4 | 15.8 | 327 |
50 | 0.6 | 1.4 | 17.8 | 400 |
100 | 0.6 | 1.8 | 28.8 | 783 |
Electrical Details | 0.4 | 0.5 | 0.6 | 0.8 | 0.9 | |
---|---|---|---|---|---|---|
Conductor Resistance (Max.av.) | 144 | 92.1 | 63.9 | 35.3 | 28 | ohm/km |
Insulation Resistance (Min.) | 5000 | 5000 | 5000 | 5000 | 5000 | Mohm.km |
Mutual Capacitance (Max.av) | 56 | 56 | 56 | 56 | 59 | pF/m |
Capacitance Unbalance (Max.av) | 150 | 150 | 150 | 150 | 150 | pF/500m |
Test Voltage Core-Core (at 1min.) | 1000 | 1000 | 1000 | 1000 | 1000 | V.D.C |
Core-Screen (at 1 min.) | 3000 | 3000 | 3000 | 3000 | 3000 | V.D.C |
Telephone Cables JYY
- According To VDE 0815 & 189
Construction:
1- Solid plain ( or tinned) annealed copper conductor
2- PVC insulation type YJ 1
3- PVC sheath type YM 1
- Application:
Used in telephone and signal transmission, suitable for installation in dry & damp indoor environment. Laying under ground is not permissible.
No. of Pairs | Conductor Dia. (mm) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|---|
2 | 0.5 | 0.2 | 0.8 | 4.8 | 23 |
4 | 0.5 | 0.2 | 0.8 | 6.1 | 37 |
6 | 0.5 | 0.2 | 1.0 | 7.4 | 55 |
10 | 0.5 | 0.2 | 1.0 | 7.7 | 75 |
20 | 0.5 | 0.2 | 1.0 | 9.9 | 134 |
30 | 0.5 | 0.2 | 1.2 | 12.0 | 196 |
40 | 0.5 | 0.2 | 1.2 | 13.5 | 252 |
50 | 0.5 | 0.2 | 1.2 | 14.8 | 313 |
60 | 0.5 | 0.2 | 1.4 | 16.3 | 378 |
80 | 0.5 | 0.2 | 1.4 | 18.5 | 486 |
100 | 0.5 | 0.2 | 1.4 | 20.5 | 598 |
Telephone Cables JY-(ST) Y
- According To IEC 0189
Construction:
1- Solid plain ( or tinned) annealed copper conductor
2- PVC insulation type YJ 1
3- Static screen: polyester tape + drain wire + AL polyester tape
4- PVC sheath type YM 1
- Application:
For use in indoor telecommunication installation in dry and damp places. but also in the for fixed installation on outer wall of building. laying under ground is not permissible.
No. of Pairs | Conductor Dia. (mm) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|---|
2 | 0.5 | 0.2 | 0.6 | 5.2 | 28 |
4 | 0.5 | 0.2 | 0.7 | 6.1 | 41 |
6 | 0.5 | 0.2 | 0.7 | 6.8 | 52 |
8 | 0.5 | 0.2 | 0.7 | 7.1 | 62 |
10 | 0.5 | 0.2 | 0.7 | 8.2 | 83 |
20 | 0.5 | 0.2 | 1.0 | 9.9 | 134 |
30 | 0.5 | 0.2 | 1.2 | 12 | 196 |
40 | 0.5 | 0.2 | 1.2 | 13.4 | 252 |
50 | 0.5 | 0.2 | 1.2 | 14.8 | 313 |
100 | 0.5 | 0.2 | 1.6 | 23 | 700 |
No. of Pairs | Conductor Dia. (mm) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|---|
2 | 0.6 | 0.2 | 0.7 | 5.6 | 34 |
4 | 0.6 | 0.2 | 0.7 | 6.5 | 50 |
6 | 0.6 | 0.2 | 0.7 | 7.4 | 68 |
8 | 0.6 | 0.2 | 0.7 | 7.9 | 82 |
10 | 0.6 | 0.2 | 0.7 | 8.9 | 103 |
20 | 0.6 | 0.2 | 1.0 | 11.3 | 193 |
30 | 0.6 | 0.2 | 1.0 | 13.3 | 271 |
40 | 0.6 | 0.2 | 1.2 | 15.8 | 342 |
50 | 0.6 | 0.2 | 1.2 | 17.6 | 423 |
100 | 0.6 | 0.2 | 1.6 | 25.0 | 850 |
Electrical Details | 0.5 | 0.6 | |
---|---|---|---|
Conductor Resistance (Max) | 96.5 | 67 | ohm/km |
Insulation Resistance (Max.) | 5000 | 5000 | Mohm.km |
Mutual Capacitance (Max) | 120 | 120 | pF/m |
Capacitance Unbalance (Max) | 400 | 400 | pF/500m |
Test Voltage (at 1 min) | 1500 | 1500 | V.D.C |
Self Supporting
- According To IEC 708
Construction:
1- Solid plain annealed conductor
2- PE Type III ASTM-D 1248
3- Two insulated conductor twisted together
4- Pairs in 25 pair units system
5- Pairs ( or units) laid-up together to form a cable core & 25 pair units is distinguished by color binders
6- A polyester tape and Aluminum-polyester tape with drain wire form overall screen
7- Aluminum tape (0.2 mm ) coated with a copolymer (only for moisture barrier cable)
8- High tensile 7-strand steel wires as messenger for Aerial Self-Support cable
9- PE Type I ASTM-D 1248
- Application:
Aerial (unfilled) Self-Support cables with integral suspension strand suitable for aerial installation and they are used for transmission of signals in external networks.
No. of Pairs | Conductor Dia. (mm) | Support No. & Dia. (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|---|
10 | 0.4 | 7×0.9 | 1.4 | 16.3×9.1 | 140 |
15 | 0.4 | 7×0.9 | 1.4 | 17.4×8.9 | 151 |
20 | 0.4 | 7×0.9 | 1.4 | 18.3×10.3 | 190 |
30 | 0.4 | 7×0.9 | 1.4 | 19.8×12.1 | 210 |
40 | 0.4 | 7×0.9 | 1.4 | 21.0×12.8 | 250 |
50 | 0.4 | 7×0.9 | 1.4 | 22.3×14 | 307 |
60 | 0.4 | 7×0.9 | 1.4 | 23.3×14.8 | 310 |
70 | 0.4 | 7×1.2 | 1.4 | 25.1×15.8 | 391 |
NOTE:
CONDUCTOR SIZE: 0.4, 6.0, 0.8
Interphone Cables
- Construction:
1- Solid plain Annealed copper conductor 0.5 mm Earth wire of bare copper wire (optional)
2- PVC insulation type TI 1 BS 6746
3- PVC sheath type TM 1 or TYPE 6 BS 6746
- Application:
These cables are used for internal wiring for interphone systems in building.
No. of Pairs | Conductor Dia. (mm) | Insulation Thickness (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) |
---|---|---|---|---|---|
2 | 0.5 | 0.2 | 0.6 | 3.1 | 13.5 |
4 | 0.5 | 0.2 | 0.6 | 3.95 | 21.4 |
6 | 0.5 | 0.2 | 0.6 | 4.5 | 26 |
8 | 0.5 | 0.2 | 0.6 | 5 | 32 |
10 | 0.5 | 0.2 | 0.6 | 5.4 | 39 |
12 | 0.5 | 0.2 | 0.6 | 5.75 | 44 |
Electrical Details | 0.5 | |
---|---|---|
DC Resistance (Max.) | 95 | ohms/km |
Insulation Resistance (Min.) | 50 | Mohms.km @20^C |
Test Voltage | 1500 | Vrms Spark Test |
High Frequency Coaxial Cables
- Construction:
1- Inner Conductor: Plain Annealed Copper Conductor
2- Dielectric: Polyethylene
3- Shield: Plain or Tinned annealed copper
4- Sheath: PVC or PE
- Application:
Radio Frequency Cables (RFC) are manufactured for application in high quality communication apparatus as well leading wire for high frequency measuring instruments. TV down leads and localized transmitter-receiver units. Generally intended for military and civil application.
According to JIS C-3501: 75 Ohms Cables
Type | Conductor No. & Diameter of Wires (mm) | Diameter Over Insulation (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) | Attenuation @ 10 MHz (db/km) |
---|---|---|---|---|---|---|
2.5C-2V | 1×0.4 | 2.4 | 0.5 | 4 | 22 | 52 |
3C-2V | 1×0.5 | 3.1 | 0.8 | 5.4 | 41 | 42 |
3C-2W | 1×0.5 | 3.1 | 1 | 6.5 | 68 | 42 |
3C-2T | 1×0.5 | 3.1 | 1 | 7.4 | 1.3 | 42 |
5C-2V | 1×0.8 | 4.9 | 0.9 | 7.4 | 71 | 27 |
5C-2W | 1×0.8 | 4.9 | 1 | 8.3 | 102 | 27 |
7C-2V | 7×0.4 | 7.3 | 1.1 | 10.4 | 141 | 22 |
50 Ohms Coaxial Cables
Type | Conductor No. & Diameter of Wires (mm) | Diameter Over Insulation (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) | Attenuation @ 10 MHz (db/km) |
---|---|---|---|---|---|---|
2.5D-2V | 1×0.8 | 2.7 | 0.5 | 4.4 | 33 | 45 |
3D-2V | 7×0.32 | 3.2 | 0.8 | 5.4 | 44 | 47 |
3D-2W | 7×0.32 | 3.2 | 1 | 6.5 | 67 | 47 |
5D-2V | 1×1.4 | 4.8 | 0.9 | 7.3 | 78 | 27 |
5D-2W | 1×1.4 | 4.8 | 0.9 | 8 | 106 | 27 |
8D-2V | 7×0.8 | 7.8 | 1.2 | 11.1 | 178 | 20 |
8D-2W | 7×0.8 | 7.8 | 1.4 | 12.4 | 245 | 20 |
According to MIL-C-17
Type | Conductor No. & Diameter of Wires (mm) | Diameter Over Insulation (mm) | Sheath Thickness (mm) | Approx. Overall Dia. (mm) | Approx. Cable Weight (kg/km) | Attenuation @ 10 MHz (db/km) | Impedance (ohms) |
---|---|---|---|---|---|---|---|
RG-11 | 7×0.4 | 7.3 | 1 | 10.2 | 136 | 7 | 75 |
RG-58 | 19×0.18 | 2.96 | 0.72 | 4.95 | 36 | 17 | 50 |
RG-59 | 1×0.58 | 3.7 | 0.86 | 6.1 | 52 | 12 | 75 |
RG-62 | 1×0.64 | 3.71 | 0.8 | 6 | 47 | 10.5 | 93 |
RG-213 | 7×0.75 | 7.25 | 1.3 | 13 | 162 | 7 | 50 |
RG-216 | 7×0.4 | 7.2 | 1.3 | 13 | 187 | 7.5 | 75 |
Head Office: 2nd Floor , No. 61 , Miremad St ., Beheshti Ave ., TEHRAN-IRAN
Tel:+98 21 887 52014
Fax:+98 21 887 57639