+98 21 8875 2014 info@moghancableco.com

 

Interphone Cables

Hits: 2187

Interphone Cable

  • Applicable Standard: IEC 708
  • Construction :

              Solid Plain Annealed Copper Conductor 0.5 mm
              Earth wire of bare copper wire ( optional )
              Insulation: PVC Type TI 1 BS 6746
              Sheath: PVC Type TM 1 or Type 6 BS 6746

  • Application:

These cables are used for internal wiring for interphone systems in buildings.

No. of Cores
Conductor dia.Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx)Total Weight (Approx)
mm
mm
mm
mm
kg/km
2
0.5
0.2
0.6
3.1
13.5
4
0.5
0.2
0.6
3.95
21.4
6
0.5
0.2
0.6
4.5
26
8
0.5
0.2
0.6
5
32
10
0.5
0.2
0.6
5.4
39
12
0.5
0.2
0.6
5.75
44

 

Electrical Details
0.5
 
DC Resistance ( Max.)
95
Ohms/km
Insulation Resistance (Min.)
50
Mohms.km @20° C
Test voltage
1500
Vrms Spark Test