Print

N2XCY

Hits: 6109

Concentric XLPE Insulated Power Cable N2XCY

               Conductor:  Plain  Annealed  Copper Wire Or Tin  Coated Wires (class 1,2)
               Insulation  Type: XLPE
               Bedding  Material:  PVC
               Concentric material:  Copper Wire + Copper Tape
               Sheath Material:  PVC 90 - ST2

               For Outdoor Installation  In  Damp And Wet Location,  Laid Direct ln, The Ground Where Excessive Mechanical Stresses
               Are Required In Sloping And Movable Terrains And In Vertical Or Inclined Laying , As Well As In Locations  Susceptible To Sliding.
 
No. of Cores & Cross Section
Nominal Insulation Thickness
Inner Layer Diameter
Concentric Wire Diameter
Nominal Sheath Thickness
Overall Diameter (Approx.)
Total Weight (Approx.)
mm²
mm
mm
mm
mm
mm
kg/km
1×1.5 RE/1.5
0.7
0
0.5
1.4
6.8
81
1×2.5 RE/2.5
0.7
0
0.5
1.4
7.2
104
1×4 RE/4
0.7
0
0.8
1.4
8.3
148
1×6 RE/6
0.7
0
0.8
1.4
8.8
190
1×10 RE/10
0.7
0
0.8
1.4
9.6
273
1×16 RM/16
0.7
0
0.8
1.4
11
398
1×25 RM/25
0.9
0
0.9
1.4
12.5
585
1×35 RM/35
0.9
0
0.9
1.4
13.6
778
1×50 RM/50
1
0
0.9
1.4
14.9
1005
2×1.5 RE/1.5
0.7
1
0.5
1.8
12.4
220
2×2.5 RE/2.5
0.7
1
0.5
1.8
13.2
266
2×4 RE/4
0.7
1
0.8
1.8
14.7
351
2×6 RE/6
0.7
1
0.8
1.8
15.7
433
2×10 RE/10
0.7
1
0.8
1.8
17.3
590
2×16 RM/16
0.7
1
0.8
1.8
20.2
846
2×25 RM/25
0.9
1
0.9
1.8
23
1201
2×35 RM/35
0.9
1
0.9
1.8
25.2
1554
2×50 RM/50
1
1
0.9
1.8
27.8
1987
3×1.5 RE/1.5
0.7
1
0.5
1.8
12.8
241
3×2.5 RE/2.5
0.7
1
0.5
1.8
13.7
298
3×4 RE/4
0.7
1
0.8
1.8
15.3
398
3×6 RE/6
0.7
1
0.8
1.8
16.4
500
3×10 RE/10
0.7
1
0.8
1.8
18.1
693
3×16 RM/16
0.7
1
0.8
1.8
21.2
1000
3×25 RM/16
0.9
1
0.8
1.8
24
1383
3×35 RM/35
0.9
1
0.9
1.8
26.6
1880
3×35 RM/16
0.9
1
0.9
1.8
23.8
1592
3×50 RM/50
1
1
0.9
1.9
29.6
2436
3×50 RM/16
1
1
0.9
1.8
26.2
2067
4×1.5 RE/1.5
0.7
1
0.5
1.8
13.5
272
4×2.5 RE/2.5
0.7
1
0.5
1.8
14.5
341
4×4 RE/4
0.7
1
0.8
1.8
16.3
462
4×6 RE/6
0.7
1
0.8
1.8
17.5
584
4×10 RE/10
0.7
1
0.8
1.8
19.4
819
4×16 RM/16
0.7
1
0.8
1.8
22.9
1194
4×25 RM/16
0.9
1
0.9
1.8
26.2
1732
4×35 RM/35
0.9
1
0.9
1.9
29.1
2284
4×50 RM/50
1
1
0.9
1.9
29.3
2584
5×1.5 RE/1.5
0.7
1
0.5
1.8
14.3
308
5×2.5 RE/2.5
0.7
1
0.5
1.8
15.4
389
5×4 RE/4
0.7
1
0.8
1.8
17.3
528
5×6 RE/6
0.7
1
0.8
1.8
18.6
671
5×10 RE/10
0.7
1
0.8
1.8
20.8
955
5×16 RM/16
0.7
1
0.8
1.8
24.7
1400
5×25 RM/16
0.9
1
0.9
1.9
28.6
2059
5×35 RM/35
0.9
1.2
0.9
2
32.2
2746
5×50 RM/50
1
1.2
0.9
2.1
35.9
3572
3×25+16 RM/16
0.9
0.7
1
0.8
1.8
25.3
1532
3×35+16 RM/16
0.9
0.7
1
0.8
1.8
27.2
1839
3×50+25 SM/25
1
0.9
1
0.9
1.8
28.5
1360
3×70+35 SM/35
1.1
0.9
1.2
0.9
1.9
32.4
3023
3×95+50 SM/50
1.1
1
1.2
0.9
2.0
36.1
4037
 

On request, Aluminium Conductor is also available