+98 21 8875 2014 info@moghancableco.com

 

N2XCY

Hits: 2722

Concentric XLPE Insulated Power Cable N2XCY

  • Voltage Rate: 0.6/1 KV
  • Applicable Standard:  IEC 60502-1,IEC  60228, ISIRI 3569-1
  • Construciton  :

               Conductor:  Plain  Annealed  Copper Wire Or Tin  Coated Wires (class 1,2)
               Insulation  Type: XLPE
               Bedding  Material:  PVC
               Concentric material:  Copper Wire + Copper Tape
               Sheath Material:  PVC 90 - ST2

  • Maximum ConductorTemprature: 90°C
  • Application:
               For Outdoor Installation  In  Damp And Wet Location,  Laid Direct ln, The Ground Where Excessive Mechanical Stresses
               Are Required In Sloping And Movable Terrains And In Vertical Or Inclined Laying , As Well As In Locations  Susceptible To Sliding.
 
No. of Cores & Cross Section
Nominal Insulation Thickness
Inner Layer Diameter
Concentric Wire Diameter
Nominal Sheath Thickness
Overall Diameter (Approx.)
Total Weight (Approx.)
mm²
mm
mm
mm
mm
mm
kg/km
1×1.5 RE/1.5
0.7
0
0.5
1.4
6.8
81
1×2.5 RE/2.5
0.7
0
0.5
1.4
7.2
104
1×4 RE/4
0.7
0
0.8
1.4
8.3
148
1×6 RE/6
0.7
0
0.8
1.4
8.8
190
1×10 RE/10
0.7
0
0.8
1.4
9.6
273
1×16 RM/16
0.7
0
0.8
1.4
11
398
1×25 RM/25
0.9
0
0.9
1.4
12.5
585
1×35 RM/35
0.9
0
0.9
1.4
13.6
778
1×50 RM/50
1
0
0.9
1.4
14.9
1005
2×1.5 RE/1.5
0.7
1
0.5
1.8
12.4
220
2×2.5 RE/2.5
0.7
1
0.5
1.8
13.2
266
2×4 RE/4
0.7
1
0.8
1.8
14.7
351
2×6 RE/6
0.7
1
0.8
1.8
15.7
433
2×10 RE/10
0.7
1
0.8
1.8
17.3
590
2×16 RM/16
0.7
1
0.8
1.8
20.2
846
2×25 RM/25
0.9
1
0.9
1.8
23
1201
2×35 RM/35
0.9
1
0.9
1.8
25.2
1554
2×50 RM/50
1
1
0.9
1.8
27.8
1987
3×1.5 RE/1.5
0.7
1
0.5
1.8
12.8
241
3×2.5 RE/2.5
0.7
1
0.5
1.8
13.7
298
3×4 RE/4
0.7
1
0.8
1.8
15.3
398
3×6 RE/6
0.7
1
0.8
1.8
16.4
500
3×10 RE/10
0.7
1
0.8
1.8
18.1
693
3×16 RM/16
0.7
1
0.8
1.8
21.2
1000
3×25 RM/16
0.9
1
0.8
1.8
24
1383
3×35 RM/35
0.9
1
0.9
1.8
26.6
1880
3×35 RM/16
0.9
1
0.9
1.8
23.8
1592
3×50 RM/50
1
1
0.9
1.9
29.6
2436
3×50 RM/16
1
1
0.9
1.8
26.2
2067
4×1.5 RE/1.5
0.7
1
0.5
1.8
13.5
272
4×2.5 RE/2.5
0.7
1
0.5
1.8
14.5
341
4×4 RE/4
0.7
1
0.8
1.8
16.3
462
4×6 RE/6
0.7
1
0.8
1.8
17.5
584
4×10 RE/10
0.7
1
0.8
1.8
19.4
819
4×16 RM/16
0.7
1
0.8
1.8
22.9
1194
4×25 RM/16
0.9
1
0.9
1.8
26.2
1732
4×35 RM/35
0.9
1
0.9
1.9
29.1
2284
4×50 RM/50
1
1
0.9
1.9
29.3
2584
5×1.5 RE/1.5
0.7
1
0.5
1.8
14.3
308
5×2.5 RE/2.5
0.7
1
0.5
1.8
15.4
389
5×4 RE/4
0.7
1
0.8
1.8
17.3
528
5×6 RE/6
0.7
1
0.8
1.8
18.6
671
5×10 RE/10
0.7
1
0.8
1.8
20.8
955
5×16 RM/16
0.7
1
0.8
1.8
24.7
1400
5×25 RM/16
0.9
1
0.9
1.9
28.6
2059
5×35 RM/35
0.9
1.2
0.9
2
32.2
2746
5×50 RM/50
1
1.2
0.9
2.1
35.9
3572
3×25+16 RM/16
0.9
0.7
1
0.8
1.8
25.3
1532
3×35+16 RM/16
0.9
0.7
1
0.8
1.8
27.2
1839
3×50+25 SM/25
1
0.9
1
0.9
1.8
28.5
1360
3×70+35 SM/35
1.1
0.9
1.2
0.9
1.9
32.4
3023
3×95+50 SM/50
1.1
1
1.2
0.9
2.0
36.1
4037
 

On request, Aluminium Conductor is also available