Armored PVC Insulated Power Cable NYRY
- Voltage Rate: 0.6/1 KV
- Applicable Standard: IEC 60502-1,IEC 60228, ISIRI 3569-1
- Construction:
Conductor: Plain Annealed Copper Wire Or Tin Coated Wires (class 1,2)
Insulation Type: P.V.C / A
Bedding Material: P.V.C
Armor material: Galvanized Steel Wire / Aluminium Wire
Sheath Material: P.V.C - ST1
- Maximum ConductorTemprature: 70°C
- Application:
For Outdoor And Indoor Installation and Wet Location Laid Direct To The Ground, Where Mechanical Damages Are Expected To Occur.
No. of Cores & Cross Section
|
Nominal Insulation Thickness
|
Nominal Inner Layer Thickness
|
Armour Wire Diameter
|
Nominal Sheath Thickness
|
Overall Diameter (Approx)
|
Total Weight (Approx)
|
---|---|---|---|---|---|---|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
1×25 RM
1×35 RM
1×50 RM
1×70 RM
1×95 RM
1×120 RM
1×150 RM
1×185 RM
1×240 RM
1×300 RM
1×400 RM
|
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
2.6
|
1
1
1
1
1
1
1
1
1
1.2
1.2
|
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
1.6
2
2
|
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.1
2.2
|
15.6
16.9
18.4
20.4
23.2
24.8
26.6
29.0
31.7
35.7
39.6
|
475
595
744
983
1329
1591
1904
2319
2933
3703
4612
|
2×1.5 RE
2×2.5 RE
2×4 RE
2×6 RE
2×10 RE
2×16 RM
2×25 RM
2×35 RM
2×50 RM
2×70 RM
2×95 RM
2×120 RM
2×150 RM
2×185 RM
2×240 RM
2×300 RM
|
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
|
1
1
1
1
1
1
1
1
1
1.2
1.2
1.2
1.4
1.4
1.4
1.6
|
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2
2
2
2.5
2.5
2.5
2.5
|
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.1
2.2
2.4
2.5
2.7
2.8
3.0
|
13.4
14.2
16.6
17.6
19.2
22.8
25.4
27.6
30.8
36.0
40.0
43.6
48.4
53.2
58.4
64.4
|
332
383
568
650
806
1181
1525
1861
2311
3254
4109
4895
6209
7437
9132
11074
|
3×1.5 RE
3×2.5 RE
3×4 RE
3×6 RE
3×10 RE
3×16 RM
3×25 RM
3×35 RM
3×50 RM
3×70 RM
3×95 RM
3×120 RM
3×150 RM
3×185 RM
3×240 RM
3×300 RM
|
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
|
1
1
1
1
1
1
1
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
|
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2
2
2
2.5
2.5
2.5
2.5
2.5
|
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.2
2.3
2.5
2.6
2.8
3.0
3.2
|
13.8
14.7
17.3
18.4
20.1
23.9
26.7
29.3
33.5
38.2
42.5
47.4
51.4
56.6
62.8
68.8
|
363
420
630
741
934
1391
1822
2243
3047
3985
5108
6474
7701
9313
11648
14097
|
4×1.5 RE
4×2.5 RE
4×4 RE
4×6 RE
4×10 RE
4×16 RM
4×25 RM
4×35 RM
4×50 SM
4×70 SM
4×95 SM
4×120 SM
4×150 SM
4×185 SM
4×240 SM
4×300 SM
4×400 SM
|
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
2.2
2.4
2.6
|
1
1
1
1
1
1
1
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.8
|
0.9
1.25
1.25
1.25
1.25
1.6
1.6
1.6
2
2
2
2.5
2.5
2.5
2.5
2.5
3.15
|
1.8
1.8
1.8
1.8
1.8
1.8
1.9
2.0
2.0
2.2
2.3
2.5
2.6
2.7
3.0
3.1
3.5
|
14.6
16.3
18.4
19.6
21.6
25.7
29.1
31.9
33.5
37.7
42.2
46.6
51.0
55.4
62.1
67.3
77.6
|
407
563
726
859
1109
1638
2204
2737
3335
4351
5649
7164
8594
10340
13081
15821
20715
|
5×1.5 RE
5×2.5 RE
5×4 RE
5×6 RE
5×10 RE
5×16 RM
5×25 RM
5×35 RM
5×50 RM
5×70 RM
5×95 RM
5×120 RM
5×150 RM
5×185 RM
|
0.8
0.8
1
1
1
1
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2
|
1
1
1
1
1
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
|
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2
2
2.5
2.5
2.5
2.5
2.5
|
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.1
2.3
2.5
2.7
2.8
3.0
3.2
|
15.4
17.2
19.6
21.0
23.8
27.7
31.6
36.0
40.4
46.7
52.6
57.1
62.3
68.6
|
457
630
829
988
1402
1921
2605
3533
4476
6273
8095
9710
11601
14104
|
3×25+16 RM
3×35+16 RM
3×50+25 SM
3×70+35 SM
3×95+50 SM
3×120+70 SM
3×150+70 SM
3×185+95 SM
3×240+120 SM
3×300+150 SM
3×400+185 SM
|
1.2 1.0
1.2 1.0
1.4 1.2
1.4 1.2
1.6 1.4
1.6 1.4
1.8 1.4
2.0 1.6
2.2 1.6
2.4 1.8
2.6 2.0
|
1
1
1
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6
|
1.6
1.6
1.6
2
2
2
2.5
2.5
2.5
2.5
3.15
|
1.9
1.9
1.8
1.9
2
2.1
2.3
2.4
2.6
2.8
3
|
28.3
30.3
31.6
35.7
40.4
43.2
48.7
52.9
59.3
65.0
73.9
|
2055
2458
2834
3927
5083
6123
7880
9463
11914
14453
18277
|
On request, Aluminium Conductor is also available